HWK-006/6-F
Matching H16Bhoods/housings
690/400V 40/16A 6/6+
- Description
- Specifications
- Download
-
Inserts Number of contacts 6/6+PE Working current 40A Working voltage 690V Rated impulse voltage 8KV Pollution degree 3 Working current 16A Working voltage 400V Rated impulse voltage 6KV Pollution degree 3 Working voltage acc.to UL/CSA 600V/600v Insulation resistance ≥10¹⁰Ω Material Polycarbonate Flammability acc.to(UL94) V0 Limiting temperatures -40℃~+125℃ Mechanical working life(mating cycles) ≥500 Contacts Material Copper alloy Surface Silver plated Contact resistance Power area ≤3mΩ
Signal area ≤1mΩ
Terminal Screw terminal Wire gauge Power area 4-10mm²(AWG12-8)
Signal area 1-2.5mm²(AWG18-4)
Signal area 0.5Nm
Power area
Screw terminal tightening mm² 1.5 2.5 4 6 10
N.m 1.2 2 3 3 3
-
Screw terminal Contact arrangement view from termination side Designation 

HWK-006/6-F Distance for contact max.21mm

Keywords:
Previous:
Next: